So one single converter suits for all international on-board power supply voltages for rail vehicles (24 V, 36 V, 72 V and 110 V) includ-ing the tolerance range of +/- 40 % required according to EN 50155.
With regard to temperature, shock, vibration and the railway-specific EMC criteria according to EN50121-3-2, as well as radiated emissions, surge, burst and ESD strict compliance with EN50155 is provided with-out additional components. Further, the converter has an integrated hold up time of 10 ms (class S2), which makes the powerful converter really unique. A high efficiency between 89 % up to 91 % allows the HEC150W to run without any derating within the temperature range of -40 °C to 85°C according class OT4.
Standard features are inrush current limitation as well as excess voltage and excess temperature protection, in addition, the converter is open-circuit stable and continuously short-circuit proof. The power supplies suits for redundant connection for safety-critical applications. A LED on the front panel indicates the operational readiness.
The chosen PCB material was based on the experience of fire & smoke tests according to EN45545-2.
Other outputs will be available on request.
Vin/V min. - max. | Vout/V | Iout/A | Type | Order number |
---|---|---|---|---|
14,4 - 154 | 24 | 6,25 | HEC150-W | 87452401125 |
Other outputs will be available on request.